Minggu, 13 September 2009

PROSES MEREKONDISI MESIN FOTOKOPI

93 POINT CERTIFIED REFURBISHED PROCESS
Fusing Assembly
• Upper Fuser Roller
• Lower Pressure Roller
• Fuser Cleaning Pressure Roller
• Web Supply Roller>
• Paper Pickup Roller
• Lower Fuser Roller Bearings
• Upper Fuser Roller Bearings
• Heat Insolating Sleeves
• Picker Fingers
• Fusing Oil (if applicable)
• Fuser Cleaning Blade (if applicable)
• Oil Application Pad (if applicable)
• Oil Application Roller (if applicable)
Imaging Section
• Drum
• Drum Cleaning Blade
• Drum Picker Fingers
• Image Transfer Belt (if applicable)
• Laser Unit
• Black Developer
• Cyan Developer (if applicable)
• Magenta Developer (if applicable)
• Yellow Developer (if applicable)>
Charge Assembly
• Charge Corona Wire
• Charge Corona Grid
• Separation Wire
• Transfer Roller
• Charge Cleaning Blocks
Paper Feed Assembly
• Paper Feed Tire
• Bypass
• LCT
• Drawer 1
• Drawer 2
• Drawer 3
• Drawer 4
• Paper Pickup Tire
• Bypass
• LCT
• Drawer 1
• Drawer 2
• Drawer 3
• Drawer 4
• Double Feed Prevention Tire
• Bypass
• LCT
• Drawer 1
• Drawer 2
• Drawer 3
• Drawer 4 
Document Feeder
• Double Feed Prevention Tire
• Upper Fuser Roller
• Paper Feed Belt
• Paper Feed Roller
Optics 
• CCD
• Mirrors
• Exposure Lamp
• Standard White Plate
• Platen
• Slit Glass (if applicable)
• Paper Size Detection Sensors
Testing
• Test Copy Quality
• Test ADF
• Test Bypass
• Test LCT (if applicable)
• Test Duplex (if applicable)
• Test Finisher (if applicable)
• Test Staple/Sorter (if applicable)
• Test Drawer 1
• Test Drawer 2
• Test Drawer 3 (if applicable)
• Test Drawer 4 (if applicable)
• Test Print Controller (if applicable)
• Test Network Card (if applicable)
• Test Fax (if applicable)
• Test Sensors and check contacts and wire        harnesses
• Check Motors, Gears, Drive belts and cables
Cosmetics
• Copier is cleaned
• No Cracked Panels
• No Broken Hinges
• No Broken Finisher Trays
• No Broken Actuator Spikes
• LCT Cord and Plug in (if applicable)
• Finisher Cord and Plug in (if applicable)
• PFU Cord and Plug in (if applicable)
• ADF Cord and Plug in
 Before Packaging
• Retest Copier After Cleaning
• Reset PM Counters
• Toner is >50% • CR Label is Applied
• Operators Manual on CD or Paper
• Service Manual if Requested
• Check List signed by Technician
• Check List is Attached to Copier
• Printer Drivers are Tested with Copier
• Printer Driver is sent on CD (if applicable).
----------------------------------------------------------------------------------------

powered by:

powered by:
CV. KARUNIA ABADI SENTOSA | Pusat Penjualan dan Persewaan Mesin Fotocopy Yogyakarta
Twitter Delicious Facebook Digg Stumbleupon Favorites More

 